Monday, July 3, 2017

Post Construction Anti Termite Treatment Specification

Post Construction termite treatment - YouTube
Post Construction termite treatment Saurashtra Pest Control. Loading ANTI TERMITE TREATMENT DOT PEST CONTROL - Duration: Termite Treatment Pre-Construction Termite Spray - Best Termites Control - Duration: ... View Video

Images of Post Construction Anti Termite Treatment Specification

TENDER FOR CIVIL WORKS RELATED TO INSTALLATION OF HVAC SYSTEM ...
Specification described in para 6.4 of code IS-6313 (part - II) 1981. (Mode of measurement will be per Sq.m plan area.) Sq.M 960.00 111.00 106560.00 5b A 8a Post constructional measures: Anti-termite treatment to the Anti-termite treatment to the outside of foundation with chemical ... Fetch Content

Regional Office : Raipur. Pujari Chambers, 2nd Floor ...
Construction of the strong room by the premises owner should be as Bank’s Specification 13. Whether offerer is agreeable to provide Space for ATM, Owner shall treat the foundation of the building by executing pre/post-construction anti-termite treatment work. ... Read Full Source

GOVERNMENT OF INDIA BHABHA ATOMIC RESEARCH CENTRE ARCH ...
APPENDIX ‘E’- guarantee bond for anti termite treatment post or courier will also be considered provided the same is received within due date & time. Construction Plant & Machinery, equipments, ... Access Document

Photos of Post Construction Anti Termite Treatment Specification

Q - Webservices.ignou.ac.in
Q.5 Discuss how the post construction anti-termite treatment is carried out in the buildings. Q.9 Write down the specification for Jack Arch flooring and RCC flooring. The fill at the end of construction will have a total volume of 9000 m3, ... Return Document

Gmbhousing.com
PREMIUM RESIDENTIAL PROJECT - SPECIFICATION. APARTMENT FINISHES . Chemical Treatment of Pidilite. Extensive Pre & Post construction Anti-Termite Treatment will be carried out. AIR CONDITIONED GYM. Exercycle, Treadmill ... Retrieve Here

TECHNICAL SPECIFICATION VOLUME II CONTENTS
Standard specification occurs in the documents relating to this contract, Post construction inspection and testing: 6313 (Part 2) 2001 Anti Termite Measures in Buildings Part ± 2 Pre-constructional chemical treatment . 3. MORTAR ... Get Document

Www.engineeringprojects.com
Such performance guarantees shall be provided for anti-termite treatment, Use materials that contain post-consumer + half of postindustrial recycled content that totals up to 5% or 10% of total building This specification covers the Anti-Termite Treatment to the buildings ... Access Doc

Post Construction Anti Termite Treatment Specification Pictures

RITES LTD
RITES LTD OPEN TENDER NOTICE NO: specification, testing as per IS codes incl. cost of water, T&P consumable material and all 9 Post-construction anti-termite treatment to structures with application by trenching, drilling ... View This Document

Post Construction Anti Termite Treatment Specification

GENERAL SPECIFICATIONS FOR REHABILITATION AND CONSTRUCTION
2.Q. TERMITE TREATMENT 18. 2.R. TREE/SHRUB REMOVAL 18. 2.S. Retaining wall 18. General Specifications for Rehabilitation and Construction, Bid Document, Addenda, and Change Orders. 5. with proper post anchors to prevent movement of posts after concrete has set. 5. ... Get Doc

Post Construction Anti Termite Treatment Specification Images

DEPARTMENT OF ATOMIC ENERGY - DCSEM
Specification for Civil Works 2015 1 DEPARTMENT OF ATOMIC ENERGY Post construction inspection and testing: Anti Termite Measures in Buildings –Part-2- Pre-constructional chemical treatment Measures. 6313 (Part 3) ... Content Retrieval

SECTION 02362 TERMITE CONTROL PART 1 GENERAL 1.1 SUMMARY 1.2 ...
SECTION 02362 TERMITE CONTROL PART 1 GENERAL B. Warranty shall guarantee effectiveness of treatment against subterranean termite infestation for A. Allow 12 hours for drying after application before resuming construction activities. Post signs in ... Access Document

Pictures of Post Construction Anti Termite Treatment Specification

REQUIREMENT OF BRANCH PREMISES - Syndicate Bank
REQUIREMENT OF BRANCH PREMISES per Bank’s/RBI specification. क्षेत्री क भ /Regional Office Owner shall treat the foundation of the building by executing pre/post-construction anti-termite treatment work. 15. A ... Fetch This Document

AMERICAN WOOD-PRESERVERS' ASSOCIATION
The treatment meets New Zealand Specification 3640 for This eliminates the need for post-treatment drying, and it AMERICAN WOOD-PRESERVERS’ ASSOCIATION . ... Read More

VOLUME-IV Preferred Make Technical Specification
Specification occurs in the documents relating to this contract, Post construction inspection and testing: Anti Termite Measures in Buildings Part – 2 Pre-constructional chemical treatment . 3. MORTAR ... Document Viewer

RITES Ltd.
CONSTRUCTION OF AUDITORIUM AT NASC COMPLEX, PUSA, NEW DELHI Abstract of Cost for Civil Works PART-I Scheduled Items based on DSR 2007 02.035 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding ... Retrieve Here

Post Construction Anti Termite Treatment Specification

SupaTimber CCA Pressure-treated Wood Is Protected From Decay ...
SupaTimber® CCA pressure-treated wood is protected from decay and termite attack with Chromated Copper Arsenate (CCA) and is pressure treatment of certain commodities. It is the treater’s ... Retrieve Content

TENDER DOCUMENT FOR PRE-CONSTRUCTIONAL ANTI-TERMITE TREATMENT ...
PRE-CONSTRUCTIONAL ANTI-TERMITE TREATMENT OF RAILSIDE WAREHOUSE AND ANCILLARY BUILDINGS AT RWC, PAHLEJA, Technical Specification for Anti -termite Treatment 129 -131 12. Detailed Schedule of Work 132 tenders sent by courier/ registered post/ speed post will not be accepted. ... Access Content

Wood Preservation - Wikipedia
All measures that are taken to ensure a long life of wood fall under the definition wood preservation (timber treatment). utility trailer beds and non-residential construction like the wood and also act as an anti-fouling measure to prevent aquatic life from attaching to the ... Read Article

PREAMBLES TO THE BILL OF QUANTITIES - Pashmina Developers
ANTI-TERMITE TREATMENT WORKS 4. PLAIN & REINFORCED CEMENT CONCRETE WORKS 5. MASONRY WORKS If there is inconsistency between the Bill of Quantities, Specification and Drawings and in case using the R.C.C post at 3 m Intervals to a height of 1.5 m from the existing G.L with suitable ... View This Document

CENTRAL STATE FARM :- SARDARGARH (Raj.)
Fencing with R.C.C. post placed at required distance, embedded in cement For all construction works strictly canal water is to be used at site. 6. vedicides and anti-termite treatment as per specification (item of ... Read More

Termite Pest Control 9811191551 - YouTube
Termite Pest Control 9811191551 Sanjeev Sharma. Loading Pre-Construction Termite Treatment (b) Post-Construction TermiteTreatment (c) Soil Treatment. Pre-Construction Anti - termite treatment:-Chemical emulsion apply at follwing stages:- ... View Video

No comments: